Dell EMC SC7020 Storage Array

Dell EMC SC7020 Storage Array

Dell EMC SC7020

  • Expandable all-in-one unit
  • (30) 2.5” drive bays, 3U
  • 606 drives, 4PB max expansion
  • Up to 1.2M max IOPS

Tư vấn, hỏi giá, Mua hàng: Vui lòng gọi

HOTLINE: 0913324060

Đặt hàng: info@emerald.com.vn

Hàng chính hãng

Giao hàng ngay (Nội thành TP.HCM)

Nhân viên Kinh Doanh

  • Ms Sang: 0913 324 060
  • Mr Huy: 0929 668 446
  • Mr.Kha: 0358.223.136

Tư vấn kỹ thuật:

  • Mr Huy - 0929 668 446

Thông số kỹ thuật

SC Hybrid SCv3000 Series SC5020 SC7020 SC9000
Chassis Overview
Rack size 3U 3U 3U 2U
Format All-in-one unit (dual controllers, internal drive bays, network I/O) Additional capacity via optional expansion enclosures Controller unit (includes network I/O, no internal drive capacity)
Internal storage capacity 30 x 2.5” drive bays SCv3000: 16 x 3.5” bays
SCv3020: 30 x 2.5” bays
Controllers Dual hot-swappable per chassis (active/active) Single controller per chassis, deploy in active/active pairs
Processors 1 per controller
Intel Xeon E5-2603v4, 1.7GHz, 6 cores
1 per controller
Intel Xeon E5-2630v3, 2.4GHz, 8 cores
2 per controller
Intel Xeon E5-2628v3 2.5GHz, 8 cores
2 per controller
Intel Xeon E5- 2667v3, 3.2GHz, 8 cores
System memory 64GB per controller
128GB per array
128GB per controller
256GB per array
256GB per controller
512GB per array
Operating system SCOS 7.2 or higher SCOS 7.2 or higher SCOS 7.1 or higher SCOS 6.7 or higher
Expansion Capacity
Max raw capacity 1PB 2.16PB 4PB 6PB
Maximum drive count 222 222 606 1024
Supported expansion enclosures 12Gb SAS
SC400: 12 x 3.5” bays
SC420: 24 x 2.5” bays
SC460: 60 x 3.5” bays
12Gb SAS
SC400: 12 x 3.5” bays
SC420: 24 x 2.5” bays
SC460: 60 x 3.5” bays
12Gb SAS
SC400: 12 x 3.5” bays
SC420: 24 x 2.5” bays
SC460: 60 x 3.5” bays

6Gb SAS
SC200: 12 x 3.5” bays
SC220: 24 x 2.5” bays
SC280: 84 x 3.5” bays
12Gb SAS
SC400: 12 x 3.5” bays
SC420: 24 x 2.5” bays
SC460: 60 x 3.5” bays

6Gb SAS
SC200: 12 x 3.5” bays
SC220: 24 x 2.5” bays
SC280: 84 x 3.5” bays
Storage media support SAS, NL-SAS (different drive types, transfer rates and rotational speeds can be mixed in same system)
SSD: Write-intensive and read-intensive drives
HDD: 15K, 10K, 7.2K RPM
Network and Expansion I/O
Front-end-network protocols FC, iSCSI, SAS (supports simultaneous multiprotocol: iSCSI + FC or iSCSI + SAS) FC, iSCSI (supports simultaneous multiprotocol)
Max 32Gb FC ports NA 8 per array (SFP+) 24 per array (SFP+) 32 per array (SFP+)
Max 16Gb FC ports 8 per array (SFP+) 8 per array (SFP+) 24 per array (SFP+) 40 per array (SFP+)
Max 100Gb iSCSI ports NA 8 per array (QSFP28) 16 per array (SFP28) 12 per array (QSFP28)
Max 25Gb iSCSI ports NA 8 per array (QSFP28) 16 per array (SFP28) 20 per array (SFP28)
Max 10Gb iSCSI ports 16 per array (SFP+ or BASE-T) 16 per array (SFP+ or BASE-T) 32 per array (SFP+ or BASE-T) 32 per array (SFP+ or BASE-T)
Max 12Gb SAS (front-end) 8 per array 8 per array NA NA
Management ports 2 per array (1Gb BASE-T)
Back-end expansion protocols 12Gb SAS 12Gb SAS (also supports 6Gb expansion)
Max back-end expansion ports 8 8 24 40
SC Hybrid SCv3000 Series SC5020 SC7020 SC9000
Functional & Performance
Array configurations All-flash, all-HDD, or hybrid mix
Storage format Native block (SAN)
Max SAN hosts 250 500 500 500
Max initiator ports 500 1000 1000 1000
Max LUN size 500TB 500TB 500TB 500TB
Max number of LUNs 1000 2000 2000 2000
Max number of snapshots 4096 8192 16,384 32,000
Max IOPS 665,000 1,025,000 1,200,000 2,220,000
Max IOPS (with latency <1ms) 540,000 818,000 1,050,000 2,085,000
Max IOPS (80% reads, 20% writes) 231,000 330,000 346,000 502,000
Max throughput (reads) 19,000 MB/s 19,000 MB/s 29,000 MB/s 33,000 MB/s
Max throughput (writes) 9,500 MB/s 9,500 MB/s 14,000 MB/s 19,000 MB/s
Data Optimization
Auto-tiering method Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.
Auto-tiering structure Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)
RAID tiering Auto-provisions and dynamically restripes multiple RAID levels on the same tier; eliminates need to pre-allocate RAID groups
Tiering customizations User-defined profiles, option to “pin” volumes to any tier or RAID level
RAID support RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array
Thin provisioning Active by default on all volumes, operates at full performance across all features
Thin snapshots Records changes only, snapshots auto-migrate to lower-cost storage
Intelligent deduplication and compression Compression only, selectable option per volume Selectable option per volume “Deduplication + compression” mode “Compression-only” mode
Data Mobility and Migration
Replication Heterogeneous arrays (SC Series any-to-any)
Synchronous/Asynchronous via FC or iSCSI
Target/source relationships may be one-to-many or many-to-one
Supports all SC data services on source and target volumes
Change replication types and topologies on demand
Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)
Volume mobility Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section
Federated multi-array systems Live Migrate (included in base product) enables host-transparent movement of volumes among arrays Snapshots maintained/preserved during migration
Thin Import Space-efficient, non-disruptive data migration from PS Series (EqualLogic) and MD3 arrays
Thin Clones Clone standalone volumes with zero duplication of data
Clones maintain independent snapshots and replication
Ideal for VDI, test/dev, other applications that require discrete instances of common data
More efficient than dedupe for database copies
Data Protection, Disaster Recovery, Security
Business continuity Live Volume bi-directional auto-failover, auto-repair
Heterogeneous arrays (SC Series any-to-any, except SCv2000)
Continuous operations, disaster recovery, disaster avoidance
Includes third-site (tertiary) replication options with Live Volume Managed Replication
Zero RTO/RPO with customizable site failover SLAs per volume
VMware Metro Stretch Cluster, VMware Site Recovery Manager support
Thin snapshots Records changes only, snapshots auto-migrate to lower-cost storage
Replay Manager Application-consistent snapshots in Microsoft, VMware, Oracle environments
Data-at-rest encryption Supports self-encrypting drives (SEDs)
Full Disk Encryption (FCE) based on AES-256
Drives certified to FIPS 140-2 Level 2
Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3
External key manager support Gemalto’s SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v Thales EMS 200
Management
Management interface Browser-based (HTML 5)
  • CloudIQ (cloud-based storage monitoring and analytics)
  • Unisphere for SC (single-array element manager, no software installation required)
  • Unisphere Central for SC (multi-array management)

Client application

  • Dell Storage Manager – Advanced multi-array, multi-site and cross-platform (PS Series) management
Federation Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays, all SC models supported.
Scripting support Microsoft PowerShell API
RESTful API
Host OS support Microsoft Windows Server, SLES, VMware, Citrix XenServer, RedHat Microsoft Windows Server, Oracle Solaris, HP-UX, Oracle Linux, IBM AIX, Novell NetWare, SLES, Apple, HPTru64, VMware, Citrix XenServer, RedHat
Third-party application integrationt VMware, Microsoft, IBM, OpenStack, Symantec, CommVault, Foglight, Docker
Data-in-place upgrades NA Transfer drives from SC4020 head unit and any expansions enclosures directly to new SC5020 or SC7020 system. Transfer drives from SC4020 head unit and any expansions enclosures directly to new SC5020 or SC7020 system. NA
Coexistence with PS Series arrays Replication in either direction
Day-to-day management from a single interface
Thin import: space-efficient, non-disruptive data migration from PS Series arrays
Certifications VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details
Reporting/alerts Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback
Firmware updates Online, non-disruptive.
Firmware may be set to download automatically, with option to trigger installation manually if desired.
Workload management QoS, VVOLs
SC Hybrid SCv3000 Series SC5020 SC7020 SC9000
Physical
Rack size 3U 3U 3U 2U (single controller only)
Height 13.33 cm (5.25 inches) 13.33 cm (5.25 inches) 13.33 cm (5.25 inches) 8.73 cm (3.44 in)
Width 44.5 cm (17.52 inches) 44.5 cm (17.52 inches) 44.5 cm (17.52 inches) 8.73 cm (3.44 in)
Depth 78.5 cm (30.9 inches) 78.5 cm (30.9 inches) 78.5 cm (30.9 inches) 8.73 cm (3.44 in)
Weight at max configuration 24.22 kg (53.4 lb) 24.22 kg (53.4 lb) 24.22 kg (53.4 lb) 8.73 cm (3.44 in)
Weight empty 15.15 kg (33.4 lb) 15.15 kg (33.4 lb) 15.15 kg (33.4 lb) 8.73 cm (3.44 in)
Rack support ReadyRails II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes, or tooled mounting in 4-post threaded-hole racks
Power
Power/wattage 2 hot-swappable power supplies
(1378W or 1485W options available, wattage type not interchangeable after point of sale)
2 hot-swappable
1485W power supplies
2 hot-swappable 1100W 80 PLUS Energy Star Platinum-certified power supplies
Maximum output power 1378W supply option: 1378 W
1485W supply option: 1485 W
1485 W 1100 W
Maximum input power 1378W supply option: 1584 W
1485W supply option: 1688 W
1688 W 1200 W
Maximum input current 1378W supply option: 16 A
1485W supply option: 8.8 A
8.8 A 12A
Maximum inrush current 55A for 10 ms or less 55A for 10 ms or less 25A for 10 ms or less
Nominal input voltage operating range 1378W supply option: 100-240 VAC
1485W supply option: 200-240 VAC
200-240 VAC 100-240 VAC
Nominal input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Thermal output/heat dissipation (maximum) 1378W option: 5,770 BTU per hour 1485 option: 5,760 BTU per hour (all-in-one base appliance, no expansion enclosures) 5,760 BTU per hour (all-in-one base appliance, no expansion enclosures) 4,100 BTU per hour (per controller)
Environmental Operating Conditions
Operating temperature 50 - 95°F (10 - 35°C) 41 - 104°F (-5 - 40°C)
Non-operating temperature -40 - 149°F (-40 - 65°C) -40 - 149°F (-40 - 65°C)
Operating humidity ranges (non-condensing) 10% to 80% with 29°C (84.2°F) maximum dew point
Non-operating humidity (noncondensing) 5% to 95% with 33°C (91°F) maximum dew point
Inlet type NEMA 5-15/CS22.2, n°42
Services, Warranties
Services Dell ProSupport with deployment and consulting services. Optional ProSupport Plus is available offering proactive and preventative services to improve performance and stability. Dell Optimize is available for additional ongoing strategic counsel and guidance from a highly trained system analyst.
Diagnostics engine Integrated Dell Remote Access Controller (iDRAC)
System sizing Dell EMC Live Optics
Drive warranty All SSDs are warrantied for full lifetime wear-out replacement with valid service agreement. SSD warranty covers all formats: SLC, MLC an d TLC
EmeraldETL